A leaflet with details on the QMI Multiplex Monitor is available as a PDF (337K)here
Picture and technical specification and dimensions. The Multiplex Oil Mist Detection system has been designed to monitor up to 12 engine or atmospheric detectors or a combination of both.
RESPONSE TIME 500 milliseconds simultaneously on all channels
WEIGHT
Central Multiplex monitor unit (CMU): 10Kg
MAXIMUM DISTANCE
Maximum distance between Detector Heads and CMU is 100 metres.
For longer distances a larger conductor size is required.
A leaflet with details on the QMI TRIPLEX? Monitor is available as a PDF (369K)here
The new QMI TRIPLEX? monitoring system is the practical answer to meet the need for oil mist monitoring in areas where only one, two or three detectors are required.
QMI atmospheric oil mist systems identify a hazardous build-up of oil mist in confined zones.
The oil mist concentration in the atmosphere is instantly reported back to the monitor to give advance warning of dangerous conditions in order to prevent the outbreak of fires.
The detectors incorporate a small fan to ensure a positive stream of air through the sensing system and are sited in the airflow usually over the equipment being monitored..
Suggested applications are:
Hydraulic pack locations as recommended by OCIMF SIRE Programme Ships Inspection Report 11.25
The QMI TRIPLEX system is simple to install on
new or existing vessels with the following advantages:
FAST RESPONSE
NO FALSE ALARMS
EASY TO READ
NO SCANNING
All detectors are calibrated and interchangeable
User friendly working instructions
on the face plate
Detectors can be located more than 100 metres from the monitor
Minimal maintenance
Avoids major clean up operations
QMI are in the forefront of atmospheric oil mist detection. The need for such a monitoring system was first recognised when the maritime industry acknowledged that up to 65% of fires at sea are the result of oil mist leaks from areas where lubricating, fuel or hydraulic oils are under pressure causing a fine mist to collect in the atmosphere and leading to a fire. The answer is to install an oil mist detection system that will detect oil mist as it is being spread into the atmosphere and alarm long before it reaches a dangerous level. Sources of ignition can be many including exhaust pipes, turbochargers, and non-flameproof motors and static electricity.
The QMI MULTIPLEX system was originally developed in the early eighties to warn of avoidable engine damage and fires. Our customers asked if the detector was suitable to measure oil mist in the atmosphere as the engine crankcase system was by then recognised for its immediate response without any false alarms. This was a sound basis from which to start and the reliability of the proven system gives the operator confidence to act when an alarm is raised.
The marine industry trialed a new detector designed to measure oil mist in the atmosphere and Seatrade gave the design the prestigious award of a highly commended contribution to Safety at Sea in 1997. The design has since been modified to facilitate maintenance and to operate in the extreme working environments found at sea.
For more information, visit our page on the Background of Oil Mist Detection
Monitor Dimensions: 280 x 230 x 138mm
Weight: 5.20 kg
Sampling Point: Maximum 3 Alarms Switches: 2 Functional Switch: 1
Monitor case: IP65
Manual test programme except for
functional facility
Response time of detection: 0.05 seconds
Voltage: 110/240VAC.
Maximum power consumption: 100W
Self-diagnostic alarm for the monitoring system
Detector Dimension: 359 x 113 x 73 mm (including fixing)
Weight: 2.30 kg
Detector case: IP65 except fan.
12V fan, power taken from the monitor
Fixing: Flanged articulated joint.
Optional Extra:
TRIPLEX unboxed 3-way PCB 13.5 x 10 cms to simplify installation.
E & OE.