产品描述

产品规格全系列型号包装说明原装进口,特价销售

英国Waterhydraulics水压泵,Waterhydraulics马达,Waterhydraulics常规阀,Waterhydraulics比例阀元件


Valves

 
Download the Valves Data Sheet 

4-2 / 3-2

A patented range of valves that can control directional flow of corrosive fluids in hydraulic systems.

Designed specifically for fluids with low viscosity the valves offer high efficiency with minimal energy input for actuation.

Also available in 4/3 and many control functions.

4-3

A patented range of valves that can control directional flow of corrosive fluids in hydraulic systems.

Designed specifically for fluids with low viscosity the valves offer high efficiency with minimal energy input for actuation.

Also available in 4/2 & 3/2 control functions.

PO Check

Available as a bolt on option to the 4/3 and 4/2 directional control valve or as an individual valve.

The PO Check offers ** seal operation for load or pressure holding applications.

DN Range

A patented range of valves that can control the pressure of corrosive fluids in hydraulic systems.

Designed specifically for fluids with low viscosity the valves offers accurate control with high resistance to flow erosion experienced in pressure control applications.

Priority Flow

Manufactured from 316 stainless steel and special engineering polymer selected for their corrosion resistance and resilience to flow erosion.

Relief

A patented range of valves that can control the pressure of corrosive fluids in hydraulic systems.

Designed specifically for fluids with low viscosity the valves offers accurate control with high resistance to flow erosion experienced in pressure control applications.

Check

A unique range of valves that are supplied in 316 stainless steel and high grade engineering polymer as standard.

Available in 3 sizes the range offers consistent performance even after lengthy periods of inactivity.

Pressure Reducing

A patented range of valves that can control the pressure of corrosive fluids in hydraulic systems.

Designed specifically for fluids with low viscosity the valves offers accurate control with high resistance to flow erosion experienced in pressure control applications.


Motors

Totally oil free, clean and completely safe for people, processes and products.

As a result of employing advanced materials, high velocity and loaded sliding surfaces can operate effectively with water as their only coolant/lubricant.

The potential for cross contamination of the system fluid or the lubricating oil is removed.

The result is an exceptionally small light weight product.

Each bearing employs a hard/soft interface that minimises vibration and ensures a low noise and high efficiency operation.

Manufactured in A.I.S.I. 316 stainless steel as standard the product offers excellent resistance to corrosive fluids.

The materials utilised internally can be selected to suit the most appropriate combinations for not just tap water but also sea water and various other fluids.

Minimal pulsation is experienced with these units due to the multiple piston design and the high operational speeds.

The physical size of the motor in comparison to the power generated offers one of the most compact drive solutions


TYPE M3 M6 M15 M30 M60 M180
Displacement cc/rev Max
Min
3.3
-
6
4.6
18.6
15
34.6
30
70.3
63
225
104
RPM - Min *
Max **
500
4000
500
4000
500
4000
500
4000
500
4000
300
2000
Max power (kW) cont. 2.7 5.4 17.5 31 67 108
Max input (l/min) cont. 12 24 72 132 292 430
Max cont. pressure (bar) 160 160 160 160 160 160
Weight (kg) 1.5 2.2 6 10 19 82
Temperature (°C) Max
Min***
90
2
50
2
50
2
50
2
50
2
50
2
Download Drawings (PDF, DXF, Step)
Graph

Download Motors catalogue including drawings
and performance graphs

* see gearbox note
** Consult TWHC for higher operating speeds
*** Consult TWHC for antifreeze option and lower temperature conditions


Geared Motor Assemblies

A standard range of epicyclic gearboxes are available for operation below the recommended minimum speed.


Temperature

The units will generate full performance from 2°C to 50°C. For temperatures below freezing an environmentally friendly antifreeze is available; ask for the glycol data sheet. Operation above 50°C is possible, but the volumetric efficiency of the unit will be affected consult TWHC and specify the maximum operating temperature.


Filters

All incoming water to the motors must be pre-filtered to a nominal rating of 10μm (25μm absolute) with a filter element rating of ?10 = 75 or better. Return line filtration is advisable on closed loop systems. High pressure filtration may also be considered.


Shaft Loading

Radial and axial loads are not permitted on the motor output shaft.


Operation

It is advised that the motors are operated on a regular basis to ensure the appropriate starting torque is maintained.


Pumps

Totally oil free, clean and completely safe for people, processes and products.

As a result of employing advanced materials, high velocity and loaded sliding surfaces can operate effectively with water as their only coolant/lubricant.

The potential for cross contamination of the system fluid or the lubricating oil is removed.

The result is an exceptionally small light weight product.

Each bearing employs a hard/soft interface that minimises vibration and ensures a low noise and high efficiency operation.

Manufactured in A.I.S.I. 316 stainless steel as standard the product offers excellent resistance to corrosive fluids.

The materials utilised internally can be selected to suit the most appropriate combinations for not just tap water but also sea water and various other fluids.

Minimal pulsation is experienced with these units due to the multiple piston design and the high operational speeds.

Accurate flow metering is simply achieved with the control of the output shaft speed.


TYPE P1 P6 P15 P30 P60 P180

Variable

Displacement

Displacement cc/rev Max
Min
1.5
0.8
6
3.3
19
8
35
20
70.3
35
225
104
 
Max. RPM unboosted
boosted *
2000

------

1800

2000

1800

2000

1800

2000

1800

2000

1800

2000

 
Max Input power (kW) 0.55 3.8 11 19.5 42 114  
Max. water flow (l/min) 2.4 12 37.2 66 146 430  
Max cont. pressure (bar) 100 160 160 160 160 160  
Weight (kg) 1.5 2.2 8 10 19 82  
Temperature °C max**
min***
90
2
50
2
50
2
50
2
50
2
50
2
 
Drawings Download (PDF, DXF, Step)  
Graph  
Download Pumps catalogue including drawings
and performance graphs

* Pump speeds above 2000 rpm are possible under higher boost conditions, consult TWHC
** Higher temperature operation is possible consult TWHC for details
*** Consult TWHC for antifreeze option and lower temperature conditions
 


Motor Pump Assemblies

A standard range of bell housing and couplings are available for connecting the pumps to the B5 electric motor flange.


The pumps are not capable of operating with induced axial or radial loads on the output shaft. Always adopt the use of a 3 part Gear style coupling where possible. If the drive shaft/spigot location is within 0.05mm concentricity direct inline drive assemblies are permissible.

 

Variable Displacement Pump

Based on their P60 fixed displacement unit the new product operating as a pump will offer infinitely variable output upto a maximum displacement of 73cc/rev producing upto 110l/min to a maximum pressure of 160 bar on a fixed speed 4 pole 50hz motor.

Upto this point the market requirement has been satisfied by the fixed displacement design but in the search for ever increasing high energy efficient systems the variable unit allows a systems requirement to be matched exactly with the optimum power input.

Designed specifically for a new development by a Swiss company; out of Lausanne University who produce energy storage systems.

The units function as both a pump and a motor delivering high volumetric and torque efficient  performance with closed loop control via an integral electronic servo control valve.

The larger P180 225cc/rev unit we also be available later in the year boosting an impressive variable output upto a maximum power of 115kW. 

Temperature

The units will generate full performance from 2°C to 50°C. For temperatures below freezing an environmentally friendly antifreeze is available; ask for the glycol data sheet.


Operation above 50°C is possible, but the volumetric efficiency of the unit will be affected consult TWHC and specify the maximum operating temperature.

Filters

All incoming water to the pumps must be pre-filtered to a nominal rating of 10μm (25μm absolute) with a filter element rating of ?10 = 75 or better. Return line filtration is advisable on closed loop systems.


High pressure filtration may also be considered.